Hazardous Duty AC Pump

Class I, Division II

One Quarter Inch Plunger

  • Simplex Flows to 72 QPD (18 GPD)
  • Duplex Flows to 148 QPD (37 GPD)
  • Operating pressures to 5,000 PSI
  • Electrical Input – 120 VAC / 50/60 Hz

Three Eighths Inch Plunger

  • Simplex Flows to 164 QPD (41 GPD)
  • Duplex Flows to 332 QPD (83 GPD)
  • Operating pressures to 2,500 PSI
  • Electrical Input – 120 VAC / 50/60 Hz

One Half Inch Plunger

  • Simplex Flows to 296 QPD (74 GPD)
  • Duplex Flows to 588 QPD (147 GPD)
  • Operating pressures to 1,250 PSI
  • Electrical Input – 120 VAC / 50/60 Hz

NOTE:  The Sidewinder Class I, Division II pump must be installed by a certified electrician.  All conduit, connections, and wiring must meet local Class I, Div II code.
NOTE:  The pump must be connected to a 120 VAC source and will not run on alternate voltages.
NOTE:   It is the responsibility of the installer to verify all components meet local Class I, Div II code and the electrician is certified to local Class I, Div II code. The Sidewinder Class I, Div II AC Chemical Metering Pump, introducing innovation and simplicity for a more reliable, energy efficient pump that provides lower maintenance cost and ease of repair. Class 1 Division 2 AC Pump explode view Our approach to designing a better pump resulted in less moving parts. Our direct drive plunger/cam arrangement eliminates the cross head and resulting alignment issues reducing plunger and seal wear. The cartridge style plunger head assembly and one piece plunger seal arrangement allows for ease of repair and ease of changing plunger sizes in less than 10 minutes. The spring return eliminates the motor having to pull the plunger back in the cycle reducing the amount of energy required to complete a full cycle. AC Powered Chemical Metering Pump Exploded View The unique pump base allows for mounting on surface of choice, whether direct to a skid or a pump stand. The pump base provides clearance and access to the check valves for tubing and repair without interference of the mountain surface. AC Powered Chemical Metering Pump Exploded View Cartridge style pump head allows for ease of repair in replacing plungers and seals. Plunger sizes can be changed in a matter of minutes. System utilizes same packing elements as the Sidewinder pneumatic pumps. AC Powered Chemical Metering Pump Exploded View Innovation is the name of the game, and Sidewinder is leading the way with our plunger and seal design. Sidewinder uses an insert that holds the plunger seal. To change plunger sizes, simply change the insert, plunger and plunger seal. Plungers come in Ceramic coated as standard, providing excellent chemical resistance and wear life. The entire assembly is mounted to the drive housing using only 4 fasteners, and can be removed in a matter of minutes. AC Powered Chemical Metering Pump Exploded View Sidewinder AC pumps use the same seal arrangements as our pneumatic pumps. Chevron or adjustable style packing allows the operator to over tighten the packing creating excessive drag on the plunger, resulting in greater energy draw, which shortens battery life. With our innovative design, seals can be changed in matter of minutes without having to dig them out with tools that can mar or damage the seal gland.

New Stroke Length Adjuster

Timer Sidewinder Pumps introduces our new Stroke Length Adjuster for AC / Solar Pump lines. The innovative design allows for 0-100% adjustment while pump is running. This provides accurate flow control options especially on duplex pumps with different size plungers. Setting the Stroke Adjuster to 0 will allow maintenance to be done to that pump without having to take pump out of service. The Stroke Adjuster can be retrofitted to existing pumps.

Additional information

Weight 39-43.0 lbs
Dimensions 12.25 × 13 × 15 in